In short
- Paid back in
- 12.3–29.7 years 20 panels facing south in 20 cities.
- Net over 25 years
- −23 587 kr–153 988 kr The lowest and the highest of the cities.
- Solar per kW
- 889–1,061 kWh Per kW of panels a year, facing south.
East and west give almost the same
We looked at a house in Stockholm with 20 panels and no battery.
Only the direction and the pitch of the roof change, so the differences come from the roof and nothing else.
With the 27.0° roof facing east, the house gets 6 446 kWh a year. Facing west, the house gets 6 447 kWh. So the morning sun and the evening sun give about the same amount of power.
South is still best. Facing south, the same roof gives 8 165 kWh a year, because the panels then face the sun in the middle of the day.
For you, this means you do not have to choose between east and west. Both sides give a large part of what a south roof gives.
On an east roof, a low pitch is best
The gap to south also depends on the pitch.
For a roof facing south a steep pitch helps, but for east and west the opposite is true. A low roof sees the sun for a larger part of the day, while a steep roof turns away from it.
In Stockholm, a 1.0° roof facing west gives 785 kWh/kWp a year. At 45.0°, the same roof gives 739 kWh/kWp. Facing east, the numbers are almost the same.
The gap is not large, but it goes the same way in all three cities. For you, this means that a flat east or west roof is a good place for panels.
It takes a few years longer to pay back
Less power means smaller savings, so the next question is what the direction means for your wallet.
With 20 panels on a 27.0° roof facing west, the house saves 7 637 kr a year. It takes 19.6 years before the system has paid for itself. Facing east, the result is about the same.
Facing south, the same house saves 9 383 kr a year, and there it takes 15.9 years. The prices in this article are after the green technology tax reduction.
For you, this means that an east or west roof in Stockholm still pays for itself within the 25 years of the calculation. You just wait a few years longer than with a south roof.
Two sides of the roof give power all day
Many houses have a gable roof with one side facing east and one facing west.
Then you can put panels on both sides. The panels facing east give power in the morning, and the panels facing west give power in the evening.
This means you get power for a longer part of the day than from one roof side. That suits a home that uses power both before and after work. Each side gives roughly the same amount of power per panel, so neither side is worse.
South of Stockholm it is faster, in the north it takes time
In the end, how good the result is depends on where you live.
In Malmö, a 27.0° roof facing west gives 852 kWh/kWp. There the house saves 10 142 kr a year, and the system has paid for itself after 14.7 years. That is faster than a south roof in Stockholm.
In the far north it looks different. In Luleå, the same roof facing west gives 721 kWh/kWp, and it takes 36.5 years before the system has paid for itself. Even facing south it takes 29.7 years there.
For you, this means that an east or west roof is a good choice in Stockholm and further south. In the north, the problem is the whole calculation, not the direction.
Work out the numbers for your own roof
All in all, east and west give almost the same power, a low pitch helps, and the numbers add up in Stockholm and Malmö.
But these numbers are for a house we worked out. Your house has its own pitch, its own shade and its own power use.
Enter your address, and we work out the numbers for the roof you really have.
20 cities: 20 panels facing south
| City | Paid back in | Net over 25 years | Solar per kW |
|---|---|---|---|
| Malmö | 12.3 years | 153 988 kr | 1,061 kWh |
| Lund | 13.6 years | 125 713 kr | 1,020 kWh |
| Växjö | 13.7 years | 123 313 kr | 933 kWh |
| Västerås | 14.2 years | 113 263 kr | 945 kWh |
| Helsingborg | 14.3 years | 112 288 kr | 969 kWh |
| Uppsala | 14.8 years | 102 213 kr | 947 kWh |
| Norrköping | 15.0 years | 99 013 kr | 968 kWh |
| Halmstad | 15.2 years | 96 838 kr | 948 kWh |
| Örebro | 15.4 years | 93 013 kr | 952 kWh |
| Stockholm | 15.9 years | 85 013 kr | 972 kWh |
| Göteborg | 16.0 years | 84 838 kr | 954 kWh |
| Jönköping | 16.0 years | 83 663 kr | 924 kWh |
| Eskilstuna | 16.0 years | 84 688 kr | 943 kWh |
| Linköping | 16.8 years | 73 338 kr | 965 kWh |
| Karlstad | 17.3 years | 66 488 kr | 969 kWh |
| Gävle | 17.6 years | 63 413 kr | 933 kWh |
| Borås | 17.7 years | 61 138 kr | 889 kWh |
| Sundsvall | 20.6 years | 32 288 kr | 909 kWh |
| Umeå | 23.9 years | 6 863 kr | 900 kWh |
| Luleå | 29.7 years | −23 587 kr | 920 kWh |
A worked example for one city is on the page about Stockholm.
Questions and answers
Do solar panels pay off on a roof facing east or west?
They can. In Stockholm, a house with 20 panels facing west saves 7 637 kr a year. It takes 19.6 years before the system has paid for itself.
Is east or west better for solar panels?
They give almost the same amount of power. In Stockholm, a 27.0° roof facing east gives 6 446 kWh a year and one facing west 6 447 kWh.
What pitch is best on an east or west roof?
A low roof gives the most. In Stockholm, a 1.0° roof facing west gives 785 kWh/kWp a year.
The data
The data behind every number on the page, per month or year. Click a dotted number to open it.
Solar per direction and pitch in Stockholm
kWh per kWp a year for the same house with the roof facing four ways at seven pitches.
| Pitch | South | East | West | North |
|---|---|---|---|---|
| 1° | 795 | 785 | 785 | 776 |
| 5° | 830 | 784 | 784 | 737 |
| 10° | 871 | 780 | 780 | 687 |
| 20° | 938 | 773 | 773 | 587 |
| 27° | 972 | 767 | 768 | 519 |
| 35° | 998 | 758 | 758 | 446 |
| 45° | 1,009 | 739 | 739 | 369 |
The reference house: 20 panels, no battery, 20 000 kWh a year, home in the day. Only the roof's direction and pitch change. kWh/kWp.
Source: data.json · roof_angles.<city>.<dir>-<pitch>.kwh_per_kwp (SolarApp.SeoArticles.RoofAngles)
Power and payback per direction in Stockholm (27°)
The same house with a 27° roof: power, savings and payback time for each direction.
| Direction | kWh/kWp | kWh a year | Saves, kr a year | Paid back, years |
|---|---|---|---|---|
| South | 972 | 8,165 | 9,383 | 15.9 |
| East | 767 | 6,446 | 7,644 | 19.6 |
| West | 768 | 6,447 | 7,637 | 19.6 |
| North | 519 | 4,356 | 5,737 | 26.1 |
The reference house: 20 panels, no battery, 20 000 kWh a year, home in the day. Only the roof's direction and pitch change.
Source: data.json · roof_angles.<city>.<dir>-<pitch>.produced_kwh, savings_kr, payback_years (SolarApp.SeoArticles.RoofAngles)
Solar per direction and pitch in Malmö
kWh per kWp a year for the same house with the roof facing four ways at seven pitches.
| Pitch | South | East | West | North |
|---|---|---|---|---|
| 1° | 888 | 878 | 878 | 869 |
| 5° | 924 | 876 | 876 | 828 |
| 10° | 964 | 872 | 872 | 775 |
| 20° | 1,029 | 861 | 861 | 667 |
| 27° | 1,061 | 852 | 852 | 591 |
| 35° | 1,083 | 838 | 838 | 506 |
| 45° | 1,088 | 813 | 813 | 413 |
The reference house: 20 panels, no battery, 20 000 kWh a year, home in the day. Only the roof's direction and pitch change. kWh/kWp.
Source: data.json · roof_angles.<city>.<dir>-<pitch>.kwh_per_kwp (SolarApp.SeoArticles.RoofAngles)
Power and payback per direction in Malmö (27°)
The same house with a 27° roof: power, savings and payback time for each direction.
| Direction | kWh/kWp | kWh a year | Saves, kr a year | Paid back, years |
|---|---|---|---|---|
| South | 1,061 | 8,912 | 12,141 | 12.3 |
| East | 852 | 7,155 | 9,937 | 15.0 |
| West | 852 | 7,155 | 10,142 | 14.7 |
| North | 591 | 4,961 | 7,539 | 19.8 |
The reference house: 20 panels, no battery, 20 000 kWh a year, home in the day. Only the roof's direction and pitch change.
Source: data.json · roof_angles.<city>.<dir>-<pitch>.produced_kwh, savings_kr, payback_years (SolarApp.SeoArticles.RoofAngles)
Solar per direction and pitch in Luleå
kWh per kWp a year for the same house with the roof facing four ways at seven pitches.
| Pitch | South | East | West | North |
|---|---|---|---|---|
| 1° | 735 | 726 | 726 | 716 |
| 5° | 771 | 724 | 724 | 677 |
| 10° | 813 | 722 | 722 | 626 |
| 20° | 883 | 720 | 720 | 526 |
| 27° | 920 | 721 | 721 | 462 |
| 35° | 950 | 719 | 719 | 397 |
| 45° | 967 | 709 | 709 | 340 |
The reference house: 20 panels, no battery, 20 000 kWh a year, home in the day. Only the roof's direction and pitch change. kWh/kWp.
Source: data.json · roof_angles.<city>.<dir>-<pitch>.kwh_per_kwp (SolarApp.SeoArticles.RoofAngles)
Power and payback per direction in Luleå (27°)
The same house with a 27° roof: power, savings and payback time for each direction.
| Direction | kWh/kWp | kWh a year | Saves, kr a year | Paid back, years |
|---|---|---|---|---|
| South | 920 | 7,730 | 5,038 | 29.7 |
| East | 721 | 6,057 | 4,081 | 36.6 |
| West | 721 | 6,057 | 4,098 | 36.5 |
| North | 462 | 3,880 | 3,001 | 49.8 |
The reference house: 20 panels, no battery, 20 000 kWh a year, home in the day. Only the roof's direction and pitch change.
Source: data.json · roof_angles.<city>.<dir>-<pitch>.produced_kwh, savings_kr, payback_years (SolarApp.SeoArticles.RoofAngles)
How we made this article
- Date of the numbers
- 2026-11-16
- Calculation
- Calculation engine v2, PVGIS weather (Oct 2026), example installer prices v12
- Text
- An AI model drafted the text from our data. A person at Numsolar checked and approved it before publishing.
- Grid fee
- Växjö: a typical grid fee, because Växjö Energi’s fee follows the spot price and the calculation cannot model that. Malmö, Örebro, Norrköping: a typical grid fee, because we have not been able to read E.ON’s price list.